CVE-2022-2069
Estado: ModificadaAlta (7.8)—
The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.45%
- Percentil entre todas las CVEs puntuadas: 37
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-122
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-2069",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-2069",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-04-16T17:26:54.288511Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Siemens",
"product": "JT2Go",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "V13.3.0.5",
"versionType": "custom"
}
]
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V13.3",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "V13.3.0.5",
"versionType": "custom"
}
]
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V14.0",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "V14.0.0.2",
"versionType": "custom"
}
]
}
]
}
],
"published": "2022-10-20T17:15:09.937",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-829738.pdf",
"tags": [
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-07",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-829738.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-07",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-122"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "El archivo APDFL.dll de Siemens JT2Go versiones anteriores a V13.3.0.5 y Siemens Teamcenter Visualization versiones anteriores a V14.0.0.2, contiene una escritura fuera de límites más allá del búfer de longitud fija en la región heap de la memoria mientras analiza archivos PDF especialmente diseñados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual"
}
],
"lastModified": "2026-06-17T04:41:13.797",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C5066383-1E8D-45FA-B1C8-6236A7C3EF18",
"versionEndExcluding": "13.3.0.5"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "77E12601-AD9F-4C83-88DF-76ECC47D13EB",
"versionEndExcluding": "13.3.0.5",
"versionStartIncluding": "13.3.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "473AED3C-AF36-4A74-A367-33D093CD0CEE",
"versionEndExcluding": "14.0.0.2",
"versionStartIncluding": "14.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}