« Volver al listado

CVE-2022-0915

Estado: ModificadaAlta (7)—

There is a Time-of-check Time-of-use (TOCTOU) Race Condition Vulnerability in Logitech Sync for Windows prior to 2.4.574. Successful exploitation of these vulnerabilities may escalate the permission to the system user.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-0915",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.9,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.4,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cve-coordination@logitech.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 0.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1
      }
    ]
  },
  "affected": [
    {
      "source": "cve-coordination@logitech.com",
      "affectedData": [
        {
          "vendor": "Logitech",
          "product": "Sync",
          "versions": [
            {
              "status": "affected",
              "version": "prior to 2.4.574",
              "lessThan": "2.4.574",
              "versionType": "custom"
            }
          ],
          "platforms": [
            "Windows"
          ]
        }
      ]
    }
  ],
  "published": "2022-04-12T19:15:07.277",
  "references": [
    {
      "url": "https://prosupport.logi.com/hc/en-us/articles/360040085114-Download-Logitech-Sync",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cve-coordination@logitech.com"
    },
    {
      "url": "https://prosupport.logi.com/hc/en-us/articles/360040085114-Download-Logitech-Sync",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cve-coordination@logitech.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-367"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-367"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is a Time-of-check Time-of-use (TOCTOU) Race Condition Vulnerability in Logitech Sync for Windows prior to 2.4.574. Successful exploitation of these vulnerabilities may escalate the permission to the system user."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de condición de carrera de tiempo de comprobación (TOCTOU) en Logitech Sync para Windows versiones anteriores a 2.4.574. Una explotación con éxito de estas vulnerabilidades puede escalar el permiso al usuario del sistema"
    }
  ],
  "lastModified": "2026-06-17T04:21:28.850",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:logitech:sync:*:*:*:*:*:windows:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7753A4B8-17AF-4DCA-B5EF-BB56B9EF5208",
              "versionEndExcluding": "2.4.574"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve-coordination@logitech.com"
}