« Volver al listado

CVE-2021-45034

Estado: ModificadaAlta (7.5)—

A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (4)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-45034",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "CP-8000 MASTER MODULE WITH I/O -25/+70°C",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V16.20"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "CP-8000 MASTER MODULE WITH I/O -40/+70°C",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V16.20"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "CP-8021 MASTER MODULE",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V16.20"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "CP-8022 MASTER MODULE WITH GPRS",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V16.20"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-01-11T12:15:10.143",
  "references": [
    {
      "url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "http://seclists.org/fulldisclosure/2022/Apr/20",
      "tags": [
        "Exploit",
        "Mailing List",
        "Third Party Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://seclists.org/fulldisclosure/2022/Apr/20",
      "tags": [
        "Exploit",
        "Mailing List",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el MÓDULO MASTER CP-8000 CON E/S -25/+70°C (Todas las versiones anteriores a V16.20), MÓDULO MASTER CP-8000 CON E/S -40/+70°C (Todas las versiones anteriores a V16.20), MÓDULO MASTER CP-8021 (Todas las versiones anteriores a V16.20), MÓDULO MASTER CP-8022 CON GPRS (Todas las versiones anteriores a V16.20). El servidor web del sistema afectado permite el acceso a los archivos de registro y datos de diagnóstico generados por un usuario privilegiado. Un atacante no autenticado podría acceder a los archivos conociendo los enlaces de descarga correspondientes"
    }
  ],
  "lastModified": "2026-06-17T04:13:04.427",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp-8000_master_module_with_i\\/o_-25\\/\\+70_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6C5EE859-1395-4644-A272-3CA2823E2D26",
              "versionEndExcluding": "16.20"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp-8000_master_module_with_i\\/o_-25\\/\\+70:*:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "9836DAE0-946B-4B65-98DF-2B82F7F3AF94"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp-8000_master_module_with_i\\/o_-40\\/\\+70_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9A9D8EE5-3D2C-420C-9969-0910C6FB8342",
              "versionEndExcluding": "16.20"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp-8000_master_module_with_i\\/o_-40\\/\\+70:*:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4A6D94AE-9F7E-46F0-92F6-C651E0EE580B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp-8021_master_module_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8B97277D-0D30-4914-BA1E-1E5B07153A52",
              "versionEndExcluding": "16.20"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp-8021_master_module:*:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F8820652-44D8-43EF-8865-BE8E7967829E"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp-8022_master_module_with_gprs_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FEA73D9E-CFAD-4DAF-9E34-51DBD2AF6FD6",
              "versionEndExcluding": "16.20"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp-8022_master_module_with_gprs:*:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D6815071-0D49-4288-8128-B9A980ECB64C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}