Estado: ModificadaAlta (7.5)—
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.31%
- Percentil entre todas las CVEs puntuadas: 83
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (4)
CWE
- CWE-284
- CWE-532
Referencias
- http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html
- http://seclists.org/fulldisclosure/2022/Apr/20
- https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf
- http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html
- http://seclists.org/fulldisclosure/2022/Apr/20
- https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-45034",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "CP-8000 MASTER MODULE WITH I/O -25/+70°C",
"versions": [
{
"status": "affected",
"version": "All versions < V16.20"
}
]
},
{
"vendor": "Siemens",
"product": "CP-8000 MASTER MODULE WITH I/O -40/+70°C",
"versions": [
{
"status": "affected",
"version": "All versions < V16.20"
}
]
},
{
"vendor": "Siemens",
"product": "CP-8021 MASTER MODULE",
"versions": [
{
"status": "affected",
"version": "All versions < V16.20"
}
]
},
{
"vendor": "Siemens",
"product": "CP-8022 MASTER MODULE WITH GPRS",
"versions": [
{
"status": "affected",
"version": "All versions < V16.20"
}
]
}
]
}
],
"published": "2022-01-11T12:15:10.143",
"references": [
{
"url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"source": "productcert@siemens.com"
},
{
"url": "http://seclists.org/fulldisclosure/2022/Apr/20",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://seclists.org/fulldisclosure/2022/Apr/20",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-532"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en el MÓDULO MASTER CP-8000 CON E/S -25/+70°C (Todas las versiones anteriores a V16.20), MÓDULO MASTER CP-8000 CON E/S -40/+70°C (Todas las versiones anteriores a V16.20), MÓDULO MASTER CP-8021 (Todas las versiones anteriores a V16.20), MÓDULO MASTER CP-8022 CON GPRS (Todas las versiones anteriores a V16.20). El servidor web del sistema afectado permite el acceso a los archivos de registro y datos de diagnóstico generados por un usuario privilegiado. Un atacante no autenticado podría acceder a los archivos conociendo los enlaces de descarga correspondientes"
}
],
"lastModified": "2026-06-17T04:13:04.427",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:cp-8000_master_module_with_i\\/o_-25\\/\\+70_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6C5EE859-1395-4644-A272-3CA2823E2D26",
"versionEndExcluding": "16.20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cp-8000_master_module_with_i\\/o_-25\\/\\+70:*:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9836DAE0-946B-4B65-98DF-2B82F7F3AF94"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:cp-8000_master_module_with_i\\/o_-40\\/\\+70_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9A9D8EE5-3D2C-420C-9969-0910C6FB8342",
"versionEndExcluding": "16.20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cp-8000_master_module_with_i\\/o_-40\\/\\+70:*:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4A6D94AE-9F7E-46F0-92F6-C651E0EE580B"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:cp-8021_master_module_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8B97277D-0D30-4914-BA1E-1E5B07153A52",
"versionEndExcluding": "16.20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cp-8021_master_module:*:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F8820652-44D8-43EF-8865-BE8E7967829E"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:cp-8022_master_module_with_gprs_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FEA73D9E-CFAD-4DAF-9E34-51DBD2AF6FD6",
"versionEndExcluding": "16.20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cp-8022_master_module_with_gprs:*:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D6815071-0D49-4288-8128-B9A980ECB64C"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}