CVE-2021-44792
Estado: ModificadaMedia (5.3)—
Single Connect does not perform an authorization check when using the "log-monitor" module. A remote attacker could exploit this vulnerability to access the logging interface. The exploitation of this vulnerability might allow a remote attacker to obtain sensitive information.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.99%
- Percentil entre todas las CVEs puntuadas: 61
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-862
- CWE-862
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-44792",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "iletisim@usom.gov.tr",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "iletisim@usom.gov.tr",
"affectedData": [
{
"vendor": "Kron",
"product": "Single Connect",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "2.16",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2022-01-27T13:15:07.837",
"references": [
{
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-22-0093",
"source": "iletisim@usom.gov.tr"
},
{
"url": "https://www.usom.gov.tr/bildirim/tr-22-0093",
"tags": [
"Third Party Advisory"
],
"source": "iletisim@usom.gov.tr"
},
{
"url": "https://www.usom.gov.tr/bildirim/tr-22-0093",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "iletisim@usom.gov.tr",
"description": [
{
"lang": "en",
"value": "CWE-862"
}
]
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-862"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Single Connect does not perform an authorization check when using the \"log-monitor\" module. A remote attacker could exploit this vulnerability to access the logging interface. The exploitation of this vulnerability might allow a remote attacker to obtain sensitive information."
},
{
"lang": "es",
"value": "Single Connect no lleva a cabo una comprobación de autorización cuando es usado el módulo \"log-monitor\". Un atacante remoto podría aprovechar esta vulnerabilidad para acceder a la interfaz de registro. La explotación de esta vulnerabilidad podría permitir a un atacante remoto obtener información confidencial"
}
],
"lastModified": "2026-06-17T04:12:51.177",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:krontech:single_connect:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "17FCFA54-8B9D-4A06-8776-9B79A20C42CB",
"versionEndExcluding": "2.16"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "iletisim@usom.gov.tr"
}