CVE-2021-44000
A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.80%
- Percentil entre todas las CVEs puntuadas: 78
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-122
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-44000",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "JT2Go",
"versions": [
{
"status": "affected",
"version": "All versions < V13.2.0.7"
}
]
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2021",
"versions": [
{
"status": "affected",
"version": "All versions < SE2021MP9"
}
]
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2022",
"versions": [
{
"status": "affected",
"version": "All versions < SE2022MP1"
}
]
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V13.1",
"versions": [
{
"status": "affected",
"version": "All versions < V13.1.0.9"
}
]
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V13.2",
"versions": [
{
"status": "affected",
"version": "All versions < V13.2.0.7"
}
]
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V13.3",
"versions": [
{
"status": "affected",
"version": "All versions < V13.3.0.1"
}
]
}
]
}
],
"published": "2022-02-09T16:15:14.107",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-335/",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-122"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.7), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP9), Solid Edge SE2022 (Todas las versiones anteriores a SE2022MP1), Teamcenter Visualization V13.1 (Todas las versiones anteriores a V13.1.0.9), Teamcenter Visualization V13.2 (Todas las versiones anteriores a V13.2.0.7), Teamcenter Visualization V13.3 (Todas las versiones anteriores a V13.3.0.1). El archivo plmxmlAdapterSE70.dll contiene una escritura fuera de límites más allá del búfer de longitud fija basado en la pila mientras analiza archivos PAR especialmente diseñados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-15053)"
}
],
"lastModified": "2026-06-17T04:11:46.100",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E41637A0-726E-43B9-82DA-624F3EF8DC27",
"versionEndExcluding": "13.2.0.7"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "756343AA-DB57-40F7-94FA-84BFCDEB6159"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "36B0DD28-653E-4069-AB5A-38F8EFEB36CA"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "82090774-D894-41C8-82F1-A48A8707E9BB"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BD346D22-9B5D-4A50-94E2-1F5C8D391EC3"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1466AEE0-4A5C-4E2D-80B8-43680F60FC31"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A4173D09-C317-45FF-ABA4-39E5592862F8"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack8:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EB31E019-AFE4-4FC7-8070-B685C9253F0E"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "61866294-2060-457C-9CBE-8AEAF03973F6"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1D30E398-C114-447E-9D4F-8D30B94ACF42",
"versionEndExcluding": "13.2.0.7",
"versionStartIncluding": "13.2.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E5D0F936-4ABA-4530-A915-39F7EEC42BE9",
"versionEndExcluding": "13.3.0.1",
"versionStartIncluding": "13.3.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A817DDD3-A448-46FE-8232-21E307A677F9"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}