« Volver al listado

CVE-2021-43615

Estado: ModificadaAlta (8.2)—

An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-43615",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.2,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 8.2,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.5
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    },
    {
      "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM APE1808 - BIOS",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V1.0.202N",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Field PG M5",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V22.01.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Field PG M6",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V26.01.13",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC127E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V27.01.09",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC227G",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V28.01.04",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC277G",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V28.01.04",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC277G PRO",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V28.01.04",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC327G",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V28.01.04",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC377G",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V28.01.04",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC427E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V21.01.17",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC477E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V21.01.17",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC477E PRO",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V21.01.17",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC627E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V25.02.12",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC647E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V25.02.12",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC677E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V25.02.12",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC847E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V25.02.12",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC ITP1000",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V23.01.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIPLUS IPC427E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V21.01.17",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2022-02-03T02:15:07.470",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://security.netapp.com/advisory/ntap-20220216-0010/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.insyde.com/security-pledge",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.insyde.com/security-pledge/SA-2022013",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://security.netapp.com/advisory/ntap-20220216-0010/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.insyde.com/security-pledge",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.insyde.com/security-pledge/SA-2022013",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.kb.cert.org/vuls/id/796611",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html",
      "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en HddPassword en InsydeH2O con el kernel versión 5.1 antes de 05.16.23, versión 5.2 antes de 05.26.23, versión 5.3 antes de 05.35.23, versión 5.4 antes de 05.43.22 y versión 5.5 antes de 05.51.22. Una vulnerabilidad de corrupción de memoria de SMM permite a un atacante escribir datos fijos o predecibles en la SMRAM. La explotación de este problema podría conducir a la escalada de privilegios en el SMM."
    }
  ],
  "lastModified": "2026-08-11T13:17:22.427",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8C029DED-CC74-4AFB-B5D0-C1FD8237DCAE",
              "versionEndExcluding": "5.16.23",
              "versionStartIncluding": "5.1"
            }
          ],
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E72D83AB-2E4E-420B-BA05-A8FAACFC2B23",
              "versionEndExcluding": "5.23.22",
              "versionStartIncluding": "5.2"
            }
          ],
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E66A9D0D-2B09-425B-8266-B19230B69C55",
              "versionEndExcluding": "5.32.22",
              "versionStartIncluding": "5.3"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}