CVE-2021-42060
Estado: ModificadaAlta (8.2)—
An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 8.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.35%
- Percentil entre todas las CVEs puntuadas: 27
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
- https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf
- https://security.netapp.com/advisory/ntap-20220217-0015/
- https://www.insyde.com/security-pledge
- https://www.insyde.com/security-pledge/SA-2022007
- https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf
- https://security.netapp.com/advisory/ntap-20220217-0015/
- https://www.insyde.com/security-pledge
- https://www.insyde.com/security-pledge/SA-2022007
- https://www.kb.cert.org/vuls/id/796611
- https://cert-portal.siemens.com/productcert/html/ssa-306654.html
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-42060",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.2,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 8.2,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1.5
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
},
{
"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"affectedData": [
{
"vendor": "Siemens",
"product": "RUGGEDCOM APE1808 - BIOS",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V1.0.202N",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC Field PG M5",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V22.01.10",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC Field PG M6",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V26.01.13",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC127E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V27.01.09",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC227G",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC277G",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC277G PRO",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC327G",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC377G",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC427E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V21.01.17",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC477E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V21.01.17",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC477E PRO",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V21.01.17",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC627E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V25.02.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC647E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V25.02.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC677E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V25.02.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC847E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V25.02.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ITP1000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V23.01.10",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS IPC427E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V21.01.17",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2022-02-03T02:15:07.293",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://security.netapp.com/advisory/ntap-20220217-0015/",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.insyde.com/security-pledge",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.insyde.com/security-pledge/SA-2022007",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://security.netapp.com/advisory/ntap-20220217-0015/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.insyde.com/security-pledge",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.insyde.com/security-pledge/SA-2022007",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html",
"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
},
{
"lang": "es",
"value": "Se ha descubierto un problema en el Kernel InsydeH2O 5.0 hasta la versión 05.08.41, en el Kernel 5.1 hasta la versión 05.16.41, en el Kernel 5.2 hasta la versión 05.23.22 y en el Kernel 5.3 hasta la versión 05.32.22. Una vulnerabilidad de la llamada Int15ServiceSmm SMM permite a un atacante secuestrar el flujo de ejecución del código que se ejecuta en el modo de gestión del sistema. La explotación de este problema podría conducir a la escalada de privilegios al SMM"
}
],
"lastModified": "2026-08-11T13:17:21.340",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7DCE671A-A982-4F7C-9474-BA693D001DA6",
"versionEndExcluding": "5.23.35",
"versionStartIncluding": "5.2"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "413286D7-0EE1-40ED-A0E5-C2294B937FD1",
"versionEndExcluding": "5.32.35",
"versionStartIncluding": "5.3"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A4803E0A-D93A-4863-B9F6-378C3D73F743",
"versionEndExcluding": "5.16.42",
"versionStartIncluding": "5.1"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C918F45E-5DF2-4081-8CD9-5FBF24793FE3",
"versionEndExcluding": "05.08.49",
"versionStartIncluding": "5.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}