« Volver al listado

CVE-2021-40366

Estado: ModificadaAlta (7.4)—

A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-40366",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 4.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.4,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 2.2
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Climatix POL909 (AWB module)",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V11.42"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Climatix POL909 (AWM module)",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V11.34"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-11-09T12:15:10.123",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-703715.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-703715.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-311"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Climatix POL909 (módulo AWB) (Todas las versiones anteriores a la versión V11.42), Climatix POL909 (módulo AWM) (Todas las versiones anteriores a la versión V11.34). El servidor web de los dispositivos afectados transmite datos sin cifrado TLS. Esto podría permitir a un atacante remoto no autenticado en una posición de hombre en el medio leer datos sensibles, como credenciales de administrador, o modificar los datos en tránsito."
    }
  ],
  "lastModified": "2026-06-17T04:06:48.547",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:climatix_pol909_firmware:*:*:*:*:advanced_web_module:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D94C8135-573A-4100-A21B-3883602414A1",
              "versionEndExcluding": "11.34"
            },
            {
              "criteria": "cpe:2.3:o:siemens:climatix_pol909_firmware:*:*:*:*:advanced_web_and_bacnet_module:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A087B863-A233-40FF-B8F8-72D9D253F37D",
              "versionEndExcluding": "11.42"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:climatix_pol909:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "256380A1-0197-4FED-AF9B-E05D59C7D1F1"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}