« Volver al listado

CVE-2021-37203

Estado: ModificadaAlta (7.1)—

A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-37203",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 4.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.1,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "NX 1980 Series",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V1984"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Solid Edge SE2021",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < SE2021MP8"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-09-14T11:15:26.473",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El archivo plmxmlAdapterIFC.dll contiene una lectura fuera de límites al analizar los archivos IFC suministrados por el usuario, lo que podría dar lugar a una lectura más allá del final de un búfer asignado. Esto podría permitir a un atacante causar una condición de denegación de servicio o leer información sensible de ubicaciones de memoria"
    }
  ],
  "lastModified": "2026-06-17T04:00:15.527",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D3A09766-0171-4DDA-9BF9-D379DA134571",
              "versionEndExcluding": "1984"
            }
          ],
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "576A303A-66CA-4694-AA54-9EB0137C24F1",
              "versionEndExcluding": "se2021"
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD"
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67"
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "756343AA-DB57-40F7-94FA-84BFCDEB6159"
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "36B0DD28-653E-4069-AB5A-38F8EFEB36CA"
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "82090774-D894-41C8-82F1-A48A8707E9BB"
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BD346D22-9B5D-4A50-94E2-1F5C8D391EC3"
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1466AEE0-4A5C-4E2D-80B8-43680F60FC31"
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A4173D09-C317-45FF-ABA4-39E5592862F8"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}