CVE-2021-37201
Estado: ModificadaAlta (8.8)—
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). The web interface of affected devices is vulnerable to a Cross-Site Request Forgery (CSRF) attack. This could allow an attacker to manipulate the SINEC NMS configuration by tricking an unsuspecting user with administrative privileges to click on a malicious link.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.43%
- Percentil entre todas las CVEs puntuadas: 35
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-352
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-37201",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SINEC NMS",
"versions": [
{
"status": "affected",
"version": "All versions < V1.0 SP1"
}
]
}
]
}
],
"published": "2021-09-14T11:15:26.313",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-330339.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-330339.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). The web interface of affected devices is vulnerable to a Cross-Site Request Forgery (CSRF) attack. This could allow an attacker to manipulate the SINEC NMS configuration by tricking an unsuspecting user with administrative privileges to click on a malicious link."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones anteriores a V1.0 SP1). La interfaz web de los dispositivos afectados es vulnerable a un ataque de tipo Cross-Site Request Forgery (CSRF). Esto podría permitir a un atacante manipular la configuración de SINEC NMS engañando a un usuario desprevenido con privilegios administrativos para que haga clic en un enlace malicioso"
}
],
"lastModified": "2026-06-17T04:00:15.327",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinec_network_management_system:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EBC16A76-8936-4D39-B6E4-7D23D361411B",
"versionEndExcluding": "1.0"
},
{
"criteria": "cpe:2.3:a:siemens:sinec_network_management_system:1.0:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F7955F92-E805-4C9C-A749-3FF264B16E31"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}