« Volver al listado

CVE-2021-37191

Estado: ModificadaMedia (4.3)—

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). An unauthenticated attacker in the same network of the affected system could brute force the usernames from the affected software.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-37191",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2021-37191",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-23T13:22:09.320973Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 3.3,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEMA Remote Connect Server",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V3.0 SP2"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-09-14T11:15:26.013",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-799"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). An unauthenticated attacker in the same network of the affected system could brute force the usernames from the affected software."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.0 SP2). Un atacante no autenticado en la misma red del sistema afectado podría forzar los nombres de usuario del software afectado"
    }
  ],
  "lastModified": "2026-06-17T04:00:13.857",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F65F9901-F4BD-4484-9749-D5022245D686",
              "versionEndExcluding": "3.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4F03BAD5-7B90-4212-ACBC-3C878C02CDAA"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E5BACE03-50A7-4279-8CA5-2BB95224D485"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}