« Volver al listado

CVE-2021-37174

Estado: ModificadaAlta (8.8)—

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices have a privilege escalation vulnerability, if exploited, an attacker could gain root user access.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (10)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-37174",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "authentication": "SINGLE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX MX5000",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX1400",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX1500",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX1501",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX1510",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX1511",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX1512",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX1524",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX1536",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM ROX RX5000",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2.14.1"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-09-14T11:15:25.273",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-250"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices have a privilege escalation vulnerability, if exploited, an attacker could gain root user access."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en RUGGEDCOM ROX MX5000 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1400 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1500 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1501 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1510 (Todas las versiones anteriores a V2. 14.1), RUGGEDCOM ROX RX1511 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1512 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1524 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1536 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX5000 (Todas las versiones anteriores a V2.14.1). Los dispositivos afectados presentan una vulnerabilidad de escalada de privilegios, si es explotado, un atacante podría conseguir acceso de usuario root"
    }
  ],
  "lastModified": "2026-06-17T04:00:11.397",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1400_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D5538013-C23A-4D6D-8756-8BE210EBEA53",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "12BD4008-DB6A-4749-A426-D2DE44819A9D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_mx5000_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "183C516E-5BD4-4B50-841F-82AC3F68D12F",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "DAD1B18F-9C37-48CC-92E2-9C5E66B206CB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1500_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6A64F21F-30C7-4164-A791-2AE72085EC8D",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3E79B422-C844-411C-AA49-CFD73D3C6E2D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1501_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9E7941A4-2B67-4B27-ACB2-E53449AD766F",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "53AAEC5C-06EE-4C58-A981-EBF5860CEF16"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1510_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "411252B0-9AE4-41F9-876C-A5863CFFA23C",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "0751225A-6E9C-4281-93A4-A048920FF7C6"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1511_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "AF574446-EE25-4603-A831-E4766B5E234F",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8C1E56ED-1E61-4B7E-8EC0-BB2AAD57EF7B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1512_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "942464AE-7E81-43D1-9996-27B7C87C26A8",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "41ADD701-AD49-46B2-A12E-219CCED32298"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1524_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CFEC6D28-3CD1-4786-8F83-DC9A64087879",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F8C70D90-E8FA-4343-9027-152A99D79C82"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1536_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2AAFB653-F651-4366-B4B4-4185EA89E31F",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C1775F3B-6F47-4134-8B4E-CF6337FF546C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx5000_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4E0625F9-DCD4-4DF6-9479-3DAE4BDB6976",
              "versionEndExcluding": "2.14.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1E0E33F2-E89B-4008-BED2-CF2296801078"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}