« Volver al listado

CVE-2021-35535

Estado: ModificadaAlta (8.1)—

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (3)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-35535",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@hitachienergy.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.4
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.2
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@hitachienergy.com",
      "affectedData": [
        {
          "vendor": "Hitachi Energy",
          "product": "Relion 670 Series",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.2 all revisions"
            },
            {
              "status": "affected",
              "version": "2.2.3",
              "lessThan": "2.2.3.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "vendor": "Hitachi Energy",
          "product": "Relion 670/650 Series",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.0 all revisions"
            },
            {
              "status": "affected",
              "version": "2.2.4 all revisions"
            }
          ]
        },
        {
          "vendor": "Hitachi Energy",
          "product": "Relion 670/650/SAM600-IO",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.1 all revisions"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-11-18T16:15:08.450",
  "references": [
    {
      "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061&LanguageCode=en&DocumentPartId=&Action=Launch",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@hitachienergy.com"
    },
    {
      "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061&LanguageCode=en&DocumentPartId=&Action=Launch",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@hitachienergy.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-1188"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-1188"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad Insecure Boot Image en Hitachi Energy Relion Relion 670/650/SAM600-IO series permite que un atacante que consiga acceder al puerto de red frontal y causar una secuencia de reinicio del dispositivo pueda explotar la vulnerabilidad, donde se presenta un pequeño espacio de tiempo durante el proceso de arranque en el que se carga una versión antigua de VxWorks antes del arranque del firmware de la aplicación, podría explotar la vulnerabilidad de la versión antigua de VxWorks y causar una denegación de servicio en el producto. Este problema afecta a: Hitachi Energy Relion 670 Series versiones 2.2.2 todas las revisiones;  versiones 2.2.3 versiones anteriores a 2.2.3.3. Hitachi Energy Relion 670/650 Series versiones 2.2.0 todas las revisiones; versiones 2.2.4 todas las revisiones. Hitachi Energy Relion 670/650/SAM600-IO versiones 2.2.1 todas las revisiones."
    }
  ],
  "lastModified": "2026-06-17T03:57:39.650",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0AA6F504-677B-4D61-BEBA-C5FF08B7EEC0",
              "versionEndIncluding": "2.2.3.3",
              "versionStartIncluding": "2.2.3"
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B91C1D5F-FE14-4121-A7C8-16F08D652610"
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A59F3E51-D3D5-4846-B8AA-6BAD4BCCCCE3"
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E368A106-A236-4A42-8608-43F47EB4A2C4"
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.4:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8F2F0B80-070C-4610-862B-346994BFEC51"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "ADA98332-543F-48A7-B63C-B39F679D47F0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EA73DFC1-3953-48DB-BF8C-545BE5B7BFAD"
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3A406AD0-38C5-4C32-AA88-AA45EE97C315"
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.4:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "48B56792-02FF-4E3E-B306-DC58FED37128"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1C658029-20F4-411A-B1FE-B4E07D590775"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DB5C50F4-CF04-4C13-868A-F7ECE49DE01B"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E73E9D1A-1DFE-4B7C-81F1-0809071A3DDB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cybersecurity@hitachienergy.com"
}