Estado: ModificadaAlta (7.3)—
A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and sufficient file-write privileges. If exploited, the attacker could place a malicious DLL file on the system, that when running XINJE XD/E Series PLC Program Tool will allow the attacker to execute arbitrary code with the privileges of another user's account.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.47%
- Percentil entre todas las CVEs puntuadas: 39
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-427
- CWE-427
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-34606",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.9,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.4,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.3
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.3
}
]
},
"affected": [
{
"source": "info@cert.vde.com",
"affectedData": [
{
"vendor": "XINJE",
"product": "XD/E Series PLC Program Tool",
"versions": [
{
"status": "affected",
"version": "unspecified",
"versionType": "custom",
"lessThanOrEqual": "v3.5.1"
}
]
}
]
}
],
"published": "2022-05-11T15:15:08.420",
"references": [
{
"url": "https://claroty.com/2022/05/11/blog-research-from-project-file-to-code-execution-exploiting-vulnerabilities-in-xinje-plc-program-tool/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "info@cert.vde.com"
},
{
"url": "https://claroty.com/2022/05/11/blog-research-from-project-file-to-code-execution-exploiting-vulnerabilities-in-xinje-plc-program-tool/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and sufficient file-write privileges. If exploited, the attacker could place a malicious DLL file on the system, that when running XINJE XD/E Series PLC Program Tool will allow the attacker to execute arbitrary code with the privileges of another user's account."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad en XINJE XD/E Series PLC Program Tool en versiones hasta v3.5.1, que puede permitir a un atacante local autenticado cargar una DLL maliciosa. Es requerido acceso local para explotar con éxito esta vulnerabilidad. Esto significa que el atacante potencial debe tener acceso al sistema y suficientes privilegios de escritura de archivos. Si es explotado, el atacante podría colocar un archivo DLL malicioso en el sistema, que cuando sea ejecutado XINJE XD/E Series PLC Program Tool, permitirá al atacante ejecutar código arbitrario con privilegios de la cuenta de otro usuario"
}
],
"lastModified": "2026-06-17T03:56:13.420",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:xinje:xd\\/e_series_plc_program_tool:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7E09E56A-B91C-43D7-8996-42B4EE6151F6",
"versionEndIncluding": "3.5.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "info@cert.vde.com"
}