CVE-2021-33842
Estado: ModificadaAlta (8.8)—
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.43%
- Percentil entre todas las CVEs puntuadas: 35
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-565
- CWE-565
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-33842",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.7,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 5.1,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve-coordination@incibe.es",
"affectedData": [
{
"vendor": "Circutor",
"product": "SGE-PLC1000",
"versions": [
{
"status": "affected",
"version": "0.9.2b"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2021-06-09T12:15:07.957",
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication",
"source": "cve-coordination@incibe.es"
},
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"description": [
{
"lang": "en",
"value": "CWE-565"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-565"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located."
},
{
"lang": "es",
"value": "Una vulnerabilidad de Autenticación Inapropiada en el parámetro cookies de Circutor SGE-PLC1000 versión del firmware 0.9.2b, permite a un atacante llevar a cabo operaciones como un usuario autenticado. Para explotar esta vulnerabilidad, el atacante debe estar dentro de la red donde se encuentra el dispositivo afectado"
}
],
"lastModified": "2026-06-17T03:55:17.827",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5D6B02E0-DE36-45F5-AD3D-908E30548661"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve-coordination@incibe.es"
}