CVE-2021-33824
Estado: ModificadaAlta (7.5)—
An issue was discovered on MOXA Mgate MB3180 Version 2.1 Build 18113012. Attackers can use slowhttptest tool to send incomplete HTTP request, which could make server keep waiting for the packet to finish the connection, until its resource exhausted. Then the web server is denial-of-service.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.93%
- Percentil entre todas las CVEs puntuadas: 79
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-400
Referencias
- https://github.com/Jian-Xian/CVE-POC/blob/master/CVE-2021-33824.md
- https://github.com/shekyan/slowhttptest
- https://www.moxa.com/en/products/industrial-edge-connectivity/protocol-gateways/modbus-tcp-gateways/mgate-mb3180-mb3280-mb3480-series
- https://github.com/Jian-Xian/CVE-POC/blob/master/CVE-2021-33824.md
- https://github.com/shekyan/slowhttptest
- https://www.moxa.com/en/products/industrial-edge-connectivity/protocol-gateways/modbus-tcp-gateways/mgate-mb3180-mb3280-mb3480-series
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-33824",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2021-06-18T20:15:07.823",
"references": [
{
"url": "https://github.com/Jian-Xian/CVE-POC/blob/master/CVE-2021-33824.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/shekyan/slowhttptest",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.moxa.com/en/products/industrial-edge-connectivity/protocol-gateways/modbus-tcp-gateways/mgate-mb3180-mb3280-mb3480-series",
"tags": [
"Product",
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/Jian-Xian/CVE-POC/blob/master/CVE-2021-33824.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://github.com/shekyan/slowhttptest",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.moxa.com/en/products/industrial-edge-connectivity/protocol-gateways/modbus-tcp-gateways/mgate-mb3180-mb3280-mb3480-series",
"tags": [
"Product",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on MOXA Mgate MB3180 Version 2.1 Build 18113012. Attackers can use slowhttptest tool to send incomplete HTTP request, which could make server keep waiting for the packet to finish the connection, until its resource exhausted. Then the web server is denial-of-service."
},
{
"lang": "es",
"value": "Se ha detectado un problema en MOXA Mgate MB3180 Versión 2.1 Build 18113012. Unos atacantes pueden usar la herramienta slowhttptest para enviar peticiones HTTP incompletas, lo que podría hacer que el servidor siga esperando el paquete para finalizar la conexión, hasta que sean agotados sus recursos. Entonces el servidor web sufre una denegación de servicio"
}
],
"lastModified": "2026-06-17T03:55:16.567",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:moxa:mgate_mb3180_firmware:2.1:build_18113012:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "710B345C-073A-4294-9EF9-C4C30D266513"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:moxa:mgate_mb3180:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EF77C838-FB6C-4A55-B5E5-FA4DDE11F3BA"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}