« Volver al listado

CVE-2021-33725

Estado: ModificadaCrítica (9.1)—

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to delete arbitrary files or directories under a user controlled path and does not correctly check if the relative path is still within the intended target directory.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-33725",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.1,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEC NMS",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V1.0 SP2 Update 1"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-10-12T10:15:11.863",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to delete arbitrary files or directories under a user controlled path and does not correctly check if the relative path is still within the intended target directory."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones anteriores a V1.0 SP2 Update 1). El sistema afectado permite eliminar archivos o directorios arbitrarios bajo una ruta controlada por el usuario y no comprueba correctamente si la ruta relativa sigue estando dentro del directorio de destino previsto"
    }
  ],
  "lastModified": "2026-06-17T03:55:06.803",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2B59D696-F272-40DA-8DC6-423D9E5026C0",
              "versionEndExcluding": "1.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5F2C66EC-5A29-4B92-AEDB-7DB8A5CA7391"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}