« Volver al listado

CVE-2021-33722

Estado: ModificadaMedia (4.9)—

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-33722",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
          "authentication": "SINGLE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEC NMS",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V1.0 SP2 Update 1"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-10-12T10:15:11.717",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones anteriores a V1.0 SP2 Update 1). El sistema afectado presenta una vulnerabilidad de Salto de Ruta cuando se exporta un contenedor de firmware. Con esto un atacante autenticado con privilegios podría crear archivos arbitrarios en un sistema afectado"
    }
  ],
  "lastModified": "2026-06-17T03:55:06.497",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2B59D696-F272-40DA-8DC6-423D9E5026C0",
              "versionEndExcluding": "1.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5F2C66EC-5A29-4B92-AEDB-7DB8A5CA7391"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}