« Volver al listado

CVE-2021-29219

Estado: ModificadaAlta (7.8)—

A potential local buffer overflow vulnerability has been identified in HPE FlexNetwork 5130 EL Switch Series version: Prior to 5130_EI_7.10.R3507P02. HPE has made the following software update to resolve the vulnerability in HPE FlexNetwork 5130 EL Switch Series version 5130_EL_7.10.R3507P02.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (7)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-29219",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.6,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "security-alert@hpe.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "HPE FlexNetwork 5130 EI Switch Series",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to 5130_EI_7.10.R3507P02"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-02-04T23:15:11.447",
  "references": [
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbnw04234en_us",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "security-alert@hpe.com"
    },
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbnw04234en_us",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A potential local buffer overflow vulnerability has been identified in HPE FlexNetwork 5130 EL Switch Series version: Prior to 5130_EI_7.10.R3507P02. HPE has made the following software update to resolve the vulnerability in HPE FlexNetwork 5130 EL Switch Series version 5130_EL_7.10.R3507P02."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una posible vulnerabilidad de desbordamiento del búfer local en HPE FlexNetwork 5130 EL Switch Series versión: Anteriores a 5130_EI_7.10.R3507P02. HPE ha realizado la siguiente actualización de software para resolver la vulnerabilidad en la versión 5130_EL_7.10.R3507P02 de HPE FlexNetwork 5130 EL Switch Series"
    }
  ],
  "lastModified": "2026-06-17T03:47:25.287",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:flexnetwork_5130_jg932a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "71C6FDDD-037F-4729-916D-198E92FE7780",
              "versionEndExcluding": "5130_ei_7.10.r3507p02"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:flexnetwork_5130_jg932a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C20270AB-31D3-45EC-AD64-7FC01F754526"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:flexnetwork_5130_jg933a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8184A743-B19B-49CD-A1B7-216B8F1E1BAB",
              "versionEndExcluding": "5130_ei_7.10.r3507p02"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:flexnetwork_5130_jg933a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "69809517-F5E5-460B-A454-CB1325870FF1"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:flexnetwork_5130_jg934a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FACFAE77-19A7-4EAF-A991-2C267E1CA613",
              "versionEndExcluding": "5130_ei_7.10.r3507p02"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:flexnetwork_5130_jg934a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "68A602B0-9BCF-487E-88DD-3B9DBF806DF5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:flexnetwork_5130_jg936a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B6094FB0-2614-4791-8350-B750ECD8E727",
              "versionEndExcluding": "5130_ei_7.10.r3507p02"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:flexnetwork_5130_jg936a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7C0924C5-D60E-4950-993B-7425A98FE082"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:flexnetwork_5130_jg937a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "482E5FFC-90DA-429D-92B7-0D8612EEE882",
              "versionEndExcluding": "5130_ei_7.10.r3507p02"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:flexnetwork_5130_jg937a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "0026C964-F3C3-4783-8875-677BA674B047"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:flexnetwork_5130_jg940a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F84DE3DE-2F7D-459D-8949-24433D5A7CF2",
              "versionEndExcluding": "5130_ei_7.10.r3507p02"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:flexnetwork_5130_jg940a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "146C3C57-3136-45C5-BB68-3DE2D5C3C6D5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:flexnetwork_5130_jg941a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "891BCCEB-7F82-4BC7-A28D-16D7EE9CD889",
              "versionEndExcluding": "5130_ei_7.10.r3507p02"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:flexnetwork_5130_jg941a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "70B5103E-1B1B-471F-9098-F412D5ED5D20"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com"
}