CVE-2021-25675
Estado: ModificadaMedia (5.5)—
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 5.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.23%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-369
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-25675",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.1,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.5,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SIMATIC S7-PLCSIM V5.4",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
]
}
],
"published": "2021-03-15T17:15:22.003",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-369"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC S7-PLCSIM versión V5.4 (todas las versiones). Un atacante con acceso local al sistema podría causar una condición de Denegación de Servicio en la aplicación cuando es usada para abrir un archivo especialmente diseñado. Como consecuencia, podría ocurrir una operación de división por cero y causar a la aplicación finalizar inesperadamente y deba reiniciarse para restaurar el servicio"
}
],
"lastModified": "2026-06-17T03:42:20.337",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim:5.4:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F5964421-8D14-4D38-B36A-EFC0E676BE65"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}