CVE-2021-25506
Estado: ModificadaMedia (5.5)—
Non-existent provider in Samsung Health prior to 6.19.1.0001 allows attacker to access it via malicious content provider or lead to denial of service.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 5.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.20%
- Percentil entre todas las CVEs puntuadas: 9
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-287
- CWE-863
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-25506",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.1,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "mobile.security@samsung.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 2.5
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.5,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "mobile.security@samsung.com",
"affectedData": [
{
"vendor": "Samsung Mobile",
"product": "Samsung Health",
"versions": [
{
"status": "affected",
"version": "-",
"lessThan": "6.19.1.0001",
"versionType": "custom"
}
]
}
]
}
],
"published": "2021-11-05T03:15:11.453",
"references": [
{
"url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021&month=11",
"tags": [
"Vendor Advisory"
],
"source": "mobile.security@samsung.com"
},
{
"url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021&month=11",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "mobile.security@samsung.com",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-863"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Non-existent provider in Samsung Health prior to 6.19.1.0001 allows attacker to access it via malicious content provider or lead to denial of service."
},
{
"lang": "es",
"value": "Un proveedor no existente en Samsung Health versiones anteriores a 6.19.1.0001, permite a un atacante acceder por medio de un proveedor de contenidos malicioso o conlleva a una denegación de servicio"
}
],
"lastModified": "2026-06-17T03:42:12.607",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:samsung:health:*:*:*:*:*:android:*:*",
"vulnerable": true,
"matchCriteriaId": "9BF7DEB0-560C-4ADB-967A-3CA6FAEEA8D7",
"versionEndExcluding": "6.19.1.0001"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "mobile.security@samsung.com"
}