CVE-2021-23288
Estado: ModificadaMedia (4.8)—
The vulnerability exists due to insufficient validation of input from certain resources by the IPP software. The attacker would need access to the local Subnet and an administrator interaction to compromise the system. This issue affects: Intelligent Power Protector versions prior to 1.69.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
- Puntuación base: 4.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.29%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-79
- CWE-79
Referencias
- https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Protector-Vulnerability-Advisory_1002b_V1.0.pdf
- https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Protector-Vulnerability-Advisory_1002b_V1.0.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-23288",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.3,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:M/Au:S/C:N/I:P/A:N",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 4.4,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "CybersecurityCOE@eaton.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.6,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 0.4
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 1.7
}
]
},
"affected": [
{
"source": "CybersecurityCOE@eaton.com",
"affectedData": [
{
"vendor": "Eaton",
"product": "Intelligent Power Protector",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "1.69",
"versionType": "custom"
}
]
}
]
}
],
"published": "2022-04-01T23:15:08.997",
"references": [
{
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Protector-Vulnerability-Advisory_1002b_V1.0.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "CybersecurityCOE@eaton.com"
},
{
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Protector-Vulnerability-Advisory_1002b_V1.0.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "CybersecurityCOE@eaton.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability exists due to insufficient validation of input from certain resources by the IPP software. The attacker would need access to the local Subnet and an administrator interaction to compromise the system. This issue affects: Intelligent Power Protector versions prior to 1.69."
},
{
"lang": "es",
"value": "La vulnerabilidad se presenta debido a una insuficiente comprobación de la entrada de determinados recursos por parte del software IPP. El atacante necesitaría acceso a la subred local y una interacción de administrador para comprometer el sistema. Este problema afecta a: Intelligent Power Protector versiones anteriores a 1.69"
}
],
"lastModified": "2026-06-17T03:38:33.593",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:eaton:intelligent_power_protector:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E8187D4D-7A38-47E5-A527-9E31527708DA",
"versionEndExcluding": "1.69"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "CybersecurityCOE@eaton.com"
}