« Volver al listado

CVE-2021-22740

Estado: ModificadaMedia (6.5)—

Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-22740",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
          "authentication": "SINGLE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior",
          "versions": [
            {
              "status": "affected",
              "version": "homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-05-26T20:15:09.220",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de Exposición de Información en homeLYnk (Wiser For KNX) y spaceLYnk versiones V2.60 y anteriores, que podría causar que la información sea expuesta cuando un archivo no autorizado es cargado"
    }
  ],
  "lastModified": "2026-06-17T03:37:41.350",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "317276F1-1B80-4CBC-92A0-8F1E7561FA16",
              "versionEndIncluding": "2.6.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F7B2FBBD-C461-47EF-A912-E445C063DED9"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:homelynk_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5E04856B-1BBF-4E36-BB26-4E03F603F645",
              "versionEndIncluding": "2.6.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:homelynk:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E5369C17-DEC4-4B14-ACFB-6CCCB6C04F1D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}