« Volver al listado

CVE-2021-0097

Estado: ModificadaMedia (6.5)—

Path traversal in the BMC firmware for Intel(R) Server Board M10JNP2SB before version EFI BIOS 7215, BMC 8100.01.08 may allow an unauthenticated user to potentially enable a denial of service via adjacent access.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-0097",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 3.3,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "secure@intel.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Intel(R) Server Board M10JNP2SB",
          "versions": [
            {
              "status": "affected",
              "version": "before version EFI BIOS 7215, BMC 8100.01.08"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-06-09T19:15:09.363",
  "references": [
    {
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00474.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "secure@intel.com"
    },
    {
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00474.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Path traversal in the BMC firmware for Intel(R) Server Board M10JNP2SB before version EFI BIOS 7215, BMC 8100.01.08 may allow an unauthenticated user to potentially enable a denial of service via adjacent access."
    },
    {
      "lang": "es",
      "value": "Un salto de ruta en el firmware del BMC para Intel® Server Board M10JNP2SB versiones anteriores a EFI BIOS 7215, BMC 8100.01.08, puede permitir a un usuario no autenticado permitir potencialmente una denegación de servicio por medio de un acceso adyacente"
    }
  ],
  "lastModified": "2026-06-17T03:29:05.890",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:efi_bios_7215:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D10744FB-5794-4C19-A120-542964E77CC1",
              "versionEndExcluding": "bmc_8100.01.08"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:server_board_m10jnp2sb:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8EAE5D89-ADEC-4F26-B555-52971EEE18A3"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "secure@intel.com"
}