CVE-2020-8751
Estado: ModificadaMedia (4.6)—
Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, Intel(R) TXE versions before 3.1.80 may allow an unauthenticated user to potentially enable information disclosure via physical access.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 4.6
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.41%
- Percentil entre todas las CVEs puntuadas: 33
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- NVD-CWE-noinfo
Referencias
- https://security.netapp.com/advisory/ntap-20201113-0002/
- https://security.netapp.com/advisory/ntap-20201113-0005/
- https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391
- https://security.netapp.com/advisory/ntap-20201113-0002/
- https://security.netapp.com/advisory/ntap-20201113-0005/
- https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-8751",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.1,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.6,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "secure@intel.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Intel(R) CSME, Intel(R) TXE",
"versions": [
{
"status": "affected",
"version": "versions before 11.8.80, Intel(R) TXE versions before 3.1.80"
}
]
}
]
}
],
"published": "2020-11-12T18:15:17.673",
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20201113-0002/",
"tags": [
"Third Party Advisory"
],
"source": "secure@intel.com"
},
{
"url": "https://security.netapp.com/advisory/ntap-20201113-0005/",
"tags": [
"Third Party Advisory"
],
"source": "secure@intel.com"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391",
"tags": [
"Vendor Advisory"
],
"source": "secure@intel.com"
},
{
"url": "https://security.netapp.com/advisory/ntap-20201113-0002/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://security.netapp.com/advisory/ntap-20201113-0005/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, Intel(R) TXE versions before 3.1.80 may allow an unauthenticated user to potentially enable information disclosure via physical access."
},
{
"lang": "es",
"value": "Una administración del flujo de control insuficiente en el subsistema para Intel® CSME versiones anteriores a 11.8.80, Intel® TXE versiones anteriores a 3.1.80, puede habilitar a un usuario no autenticado para permitir potencialmente una divulgación de información por medio de un acceso físico"
}
],
"lastModified": "2026-06-17T03:26:53.090",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BA64E7EE-8977-4427-9FF9-DD9FE80F02C6",
"versionEndExcluding": "11.8.80"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DF1D6613-FA0F-4859-B45C-A0F86BCF1CF8",
"versionEndExcluding": "3.1.80"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secure@intel.com"
}