CVE-2020-8438
Estado: ModificadaAlta (7.2)—
Ruckus ZoneFlex R500 104.0.0.0.1347 devices allow an authenticated attacker to execute arbitrary OS commands via the hidden /forms/nslookupHandler form, as demonstrated by the nslookuptarget=|cat${IFS} substring.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.59%
- Percentil entre todas las CVEs puntuadas: 75
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-8438",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-01-29T23:15:13.030",
"references": [
{
"url": "https://sku11army.blogspot.com/2020/01/ruckus-rce-ruckus-m500-via-injection-on.html",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://sku11army.blogspot.com/2020/01/ruckus-rce-ruckus-m500-via-injection-on.html",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Ruckus ZoneFlex R500 104.0.0.0.1347 devices allow an authenticated attacker to execute arbitrary OS commands via the hidden /forms/nslookupHandler form, as demonstrated by the nslookuptarget=|cat${IFS} substring."
},
{
"lang": "es",
"value": "Los dispositivos Ruckus ZoneFlex R500 versión 104.0.0.0.1347, permiten a un atacante autenticado ejecutar comandos arbitrarios del sistema operativo por medio del formulario oculto de /forms/nslookupHandler, como es demostrado por la subcadena nslookuptarget=|cat${IFS}."
}
],
"lastModified": "2026-06-17T03:26:22.940",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:arris:ruckus_zoneflex_r500_firmware:104.0.0.0.1347:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E93046E9-6A17-4052-8A0B-07BA0B8773F5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:arris:ruckus_zoneflex_r500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F0EE0BD7-1B48-4AC4-A769-F12F303054FA"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}