« Volver al listado

CVE-2020-7332

Estado: ModificadaAlta (8.8)—

Cross Site Request Forgery vulnerability in the firewall ePO extension of McAfee Endpoint Security (ENS) prior to 10.7.0 November 2020 Update allows an attacker to execute arbitrary HTML code due to incorrect security configuration.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-7332",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "trellixpsirt@trellix.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:L",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.5,
        "exploitabilityScore": 1.5
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "trellixpsirt@trellix.com",
      "affectedData": [
        {
          "vendor": "Mcafee, LLC",
          "product": "Endpoint Security for Windows",
          "versions": [
            {
              "status": "affected",
              "version": "10.7.x",
              "versionType": "custom",
              "lessThanOrEqual": "10.7.0 September 2020 Update"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-11-12T10:15:13.623",
  "references": [
    {
      "url": "https://kc.mcafee.com/corporate/index?page=content&id=SB10335",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "source": "trellixpsirt@trellix.com"
    },
    {
      "url": "https://kc.mcafee.com/corporate/index?page=content&id=SB10335",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "trellixpsirt@trellix.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cross Site Request Forgery vulnerability in the firewall ePO extension of McAfee Endpoint Security (ENS) prior to 10.7.0 November 2020 Update allows an attacker to execute arbitrary HTML code due to incorrect security configuration."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de tipo Cross Site Request Forgery en la extensión ePO del firewall de McAfee Endpoint Security (ENS) versiones anteriores a 10.7.0, actualización de Noviembre de 2020, permite a un atacante ejecutar código HTML arbitrario debido a una configuración de seguridad incorrecta"
    }
  ],
  "lastModified": "2026-06-17T03:24:43.997",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mcafee:endpoint_security:*:*:*:*:*:windows:*:*",
              "vulnerable": true,
              "matchCriteriaId": "277DF1D5-0C18-4549-875C-84828ABE7B20",
              "versionEndExcluding": "10.6.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "trellixpsirt@trellix.com"
}