CVE-2020-5807
Estado: ModificadaAlta (7.5)—
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 34%
- Percentil entre todas las CVEs puntuadas: 98
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-755
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-5807",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "vulnreport@tenable.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Rockwell FactoryTalk Diagnostics",
"versions": [
{
"status": "affected",
"version": "All versions of FactoryTalk Diagnostics"
}
]
}
]
}
],
"published": "2020-12-29T16:15:14.933",
"references": [
{
"url": "https://www.tenable.com/security/research/tra-2020-71",
"tags": [
"Third Party Advisory"
],
"source": "vulnreport@tenable.com"
},
{
"url": "https://www.tenable.com/security/research/tra-2020-71",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-755"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected."
},
{
"lang": "es",
"value": "Un atacante remoto no autenticado puede enviar datos al archivo RsvcHost.exe escuchando en el puerto TCP 5241 para agregar entradas en el registro de evento de FactoryTalk Diagnostics. El atacante puede especificar campos largos en la entrada del registro, lo que puede causar una excepción no controlada en la función wcscpy_s() si un usuario local abre FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) para visualizar la entrada del registro. Observado en FactoryTalk Diagnostics versión 6.11. Todas las versiones de FactoryTalk Diagnostics están afectadas"
}
],
"lastModified": "2026-06-17T03:22:16.407",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_diagnostics:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6DC4616B-56E2-44D3-862E-22D8E0DCF4ED",
"versionEndIncluding": "6.11"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "vulnreport@tenable.com"
}