« Volver al listado

CVE-2020-5797

Estado: ModificadaMedia (6.1)—

UNIX Symbolic Link (Symlink) Following in TP-Link Archer C9(US)_V1_180125 firmware allows an unauthenticated actor, with physical access and network access, to read sensitive files and write to a limited set of files after plugging a crafted USB drive into the router.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-5797",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 3.6,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 4.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "vulnreport@tenable.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "TP-Link Archer C9 A1",
          "versions": [
            {
              "status": "affected",
              "version": "Archer C9(US)_V1_180125 firmware"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-11-21T06:15:12.537",
  "references": [
    {
      "url": "https://www.tenable.com/security/research/tra-2020-60",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "vulnreport@tenable.com"
    },
    {
      "url": "https://www.tenable.com/security/research/tra-2020-60",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-59"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "UNIX Symbolic Link (Symlink) Following in TP-Link Archer C9(US)_V1_180125 firmware allows an unauthenticated actor, with physical access and network access, to read sensitive files and write to a limited set of files after plugging a crafted USB drive into the router."
    },
    {
      "lang": "es",
      "value": "Un Seguimiento Enlace Simbólico de UNIX (Symlink) en TP-Link Archer versiones de firmware C9(EE. UU.) _V1_180125, permite a un actor no autenticado, con acceso físico y acceso de red, leer archivos confidenciales y escribir en un conjunto limitado de archivos después de conectar una unidad USB diseñada en el enrutador"
    }
  ],
  "lastModified": "2026-06-17T03:22:15.320",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tp-link:archer_c9_firmware:180125:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FCDD6D05-37DF-4762-85B8-1CB49DBF3E90"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tp-link:archer_c9:v1:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "AE0C00A1-F050-4CF3-86A4-310145909DF2"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],