CVE-2020-5756
Estado: ModificadaAlta (8.8)—
Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.47%
- Percentil entre todas las CVEs puntuadas: 84
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-489
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-5756",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "vulnreport@tenable.com",
"affectedData": [
{
"vendor": "Tenable",
"product": "Grandstream GWN7000",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.9.4 and below"
}
]
}
]
}
],
"published": "2020-07-17T21:15:13.607",
"references": [
{
"url": "https://www.tenable.com/security/research/tra-2020-41",
"tags": [
"Not Applicable"
],
"source": "vulnreport@tenable.com"
},
{
"url": "https://www.tenable.com/cve/CVE-2020-5756",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "nvd@nist.gov"
},
{
"url": "https://www.tenable.com/security/research/tra-2020-41",
"tags": [
"Not Applicable"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "vulnreport@tenable.com",
"description": [
{
"lang": "en",
"value": "CWE-489"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router."
},
{
"lang": "es",
"value": "Grandstream GWN7000 versiones de firmware 1.0.9.4 y posterior, permite a usuarios autenticados remotos modificar el crontab del sistema por medio de una API no documentada. Un atacante puede usar esta funcionalidad para ejecutar comandos arbitrarios del Sistema Operativo en el enrutador"
}
],
"lastModified": "2026-06-17T03:22:10.677",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:gwn7000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7CE4BEAF-0CCB-4D73-BA20-2781092F7E7A",
"versionEndIncluding": "1.0.9.4"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:gwn7000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E0139B06-8FDD-4A29-B378-B917EAAD84A0"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "vulnreport@tenable.com"
}