CVE-2020-5531
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.02%
- Percentil entre todas las CVEs puntuadas: 80
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (5)
CWE
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-5531",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "vultures@jpcert.or.jp",
"affectedData": [
{
"vendor": "Mitsubishi Electric Corporation",
"product": "Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000",
"versions": [
{
"status": "affected",
"version": "MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before)"
}
]
}
]
}
],
"published": "2020-02-17T07:15:16.473",
"references": [
{
"url": "https://jvn.jp/en/vu/JVNVU95424547/index.html",
"tags": [
"Third Party Advisory"
],
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf",
"tags": [
"Vendor Advisory"
],
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://jvn.jp/en/vu/JVNVU95424547/index.html",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors."
},
{
"lang": "es",
"value": "Mitsubishi Electric MELSEC C Controller Module y MELIPC Series MI5000 MELSEC-Q Series C Controller Module (Q24DHCCPU-V, Q24DHCCPU-VG puerto User Ethernet (CH1, CH2): Primeros 5 dígitos del número de serial 21121 o anterior), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module (R12CCPU-V puerto Ethernet (CH1, CH2): Primeros 2 dígitos del número de serial 11 o anterior, y RD55UP06-V puerto Ethernet: Primeros 2 dígitos del número de serial 08 o anterior), y MELIPC Series MI5000 (MI5122-VW puerto Ethernet (CH1): Primeros 2 dígitos del número de serial 03 o anterior, o la versión de firmware 03 o anterior), permite a atacantes remotos causar una denegación de servicio (DoS) y/o un malware que se ejecuta por medio de vectores no especificados."
}
],
"lastModified": "2026-06-17T03:21:33.160",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:mi5122-vw_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "66A9D45E-95CE-42C0-B7BA-00A2402DE65C",
"versionEndIncluding": "03"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:mi5122-vw:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2054E9BB-9DC6-49DA-A215-D63A93B8160C"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:q24dhccpu-v_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E2ED90B7-7987-4C00-8D17-1F8C277A1CBA",
"versionEndIncluding": "21121"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:q24dhccpu-v:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "210A2E8A-BF20-43F5-BA07-CB662833DE1D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:q24dhccpu-vg_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3C71A2CB-E456-4BA5-A845-5B1D036E3D50",
"versionEndIncluding": "21121"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:q24dhccpu-vg:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D9DF6F77-EEB5-4CB3-B041-7BA43F16E2E3"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:r12ccpu-v_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3BF5934E-7FAD-410F-AB75-FA7BACB345DC",
"versionEndIncluding": "11"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:r12ccpu-v:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8B938943-DDD5-43DC-98A3-29D0E6AFBF85"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:rd55up06-v_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "29ED1F7F-AC02-418F-A380-6FFF2C0FB6A3",
"versionEndIncluding": "08"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:rd55up06-v:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F1F5EF13-A273-459E-815B-F21C57D44204"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp"
}