CVE-2020-35564
Estado: ModificadaAlta (7.5)—
An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an outdated and unused component allowing for malicious user input of active code.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.93%
- Percentil entre todas las CVEs puntuadas: 59
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-74
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-35564",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2021-02-16T16:15:13.427",
"references": [
{
"url": "https://cert.vde.com/de-de/advisories/vde-2021-003",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://mbconnectline.com/security-advice/",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://cert.vde.com/de-de/advisories/vde-2021-003",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://mbconnectline.com/security-advice/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-74"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an outdated and unused component allowing for malicious user input of active code."
},
{
"lang": "es",
"value": "Se detectó un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.2. Existe un componente obsoleto y sin uso que permite la entrada de código activo por parte de usuarios maliciosos"
}
],
"lastModified": "2026-06-17T03:13:56.730",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AD64D150-3FCD-4973-88EB-FDCBBC39BB4C",
"versionEndIncluding": "2.6.2"
},
{
"criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FDA4DEB0-F344-4B04-8BFD-1D405D0CED23",
"versionEndIncluding": "2.6.2"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}