« Volver al listado

CVE-2020-3392

Estado: ModificadaAlta (7.5)—

A vulnerability in the API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to view sensitive information on an affected system. The vulnerability exists because the affected software does not properly authenticate API calls. An attacker could exploit this vulnerability by sending API requests to an affected system. A successful exploit could allow the attacker to view sensitive information on the affected system, including information about the devices that the system manages, without authentication.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-3392",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2020-3392",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-13T17:12:02.630362Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "psirt@cisco.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@cisco.com",
      "affectedData": [
        {
          "vendor": "Cisco",
          "product": "Cisco IoT Field Network Director (IoT-FND)",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-11-18T18:15:12.623",
  "references": [
    {
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-APIA-xZntFS2V",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "psirt@cisco.com"
    },
    {
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-APIA-xZntFS2V",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in the API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to view sensitive information on an affected system. The vulnerability exists because the affected software does not properly authenticate API calls. An attacker could exploit this vulnerability by sending API requests to an affected system. A successful exploit could allow the attacker to view sensitive information on the affected system, including information about the devices that the system manages, without authentication."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en la API de Cisco IoT Field Network Director (FND), podría permitir a un atacante remoto no autenticado visualizar información confidencial en un sistema afectado. La vulnerabilidad se presenta porque el software afectado no autentica apropiadamente las llamadas a la API. Un atacante podría explotar esta vulnerabilidad mediante el envío peticiones a la API hacia un sistema afectado. Una explotación con éxito podría permitir al atacante visualizar información confidencial en el sistema afectado, incluyendo información sobre los dispositivos que administra el sistema, sin autenticación"
    }
  ],
  "lastModified": "2026-06-17T03:18:09.867",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0D507A4F-4079-4B68-997E-88901E063348",
              "versionEndExcluding": "4.6.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "psirt@cisco.com"
}