« Volver al listado

CVE-2020-29025

Estado: ModificadaMedia (6.1)—

A vulnerability in SiteManager-Embedded (SM-E) Web server which may allow attacker to construct a URL that if visited by another application user, will cause JavaScript code supplied by the attacker to execute within the user's browser in the context of that user's session with the application. This issue affects all versions and variants of SM-E prior to version 9.3

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-29025",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "VulnerabilityReporting@secomea.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.4,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.5,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "VulnerabilityReporting@secomea.com",
      "affectedData": [
        {
          "vendor": "Secomea",
          "product": "SiteManager Embedded (SM-E)",
          "versions": [
            {
              "status": "affected",
              "version": "all",
              "lessThan": "9.3",
              "versionType": "custom"
            }
          ],
          "platforms": [
            "all"
          ]
        }
      ]
    }
  ],
  "published": "2021-02-16T16:15:12.893",
  "references": [
    {
      "url": "https://www.secomea.com/support/cybersecurity-advisory/#3042",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "VulnerabilityReporting@secomea.com"
    },
    {
      "url": "https://www.secomea.com/support/cybersecurity-advisory/#3042",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "VulnerabilityReporting@secomea.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in SiteManager-Embedded (SM-E) Web server which may allow attacker to construct a URL that if visited by another application user, will cause JavaScript code supplied by the attacker to execute within the user's browser in the context of that user's session with the application. This issue affects all versions and variants of SM-E prior to version 9.3"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en el servidor Web de SiteManager-Embedded (SM-E), que puede permitir al atacante construir una URL que, si es visitada por otro usuario de la aplicación, causará que el código JavaScript suministrado por el atacante se ejecute dentro del navegador del usuario en el contexto de la sesión de ese usuario con la aplicación. Este problema afecta a todas las versiones y variantes de SM-E anteriores a versión 9.3"
    }
  ],
  "lastModified": "2026-06-17T03:10:59.960",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:secomea:sitemanager_embedded:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5D22EE4D-3A7A-4192-AF67-FD80D8E7DB73",
              "versionEndExcluding": "9.2c"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "VulnerabilityReporting@secomea.com"
}