CVE-2020-27892
Estado: ModificadaAlta (7.5)—
The Zigbee protocol implementation on Texas Instruments CC2538 devices with Z-Stack 3.0.1 does not properly process a ZCL Discover Commands Received Response message or a ZCL Discover Commands Generated Response message. It crashes in zclParseInDiscCmdsRspCmd().
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.46%
- Percentil entre todas las CVEs puntuadas: 73
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-27892",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-10-27T21:15:14.243",
"references": [
{
"url": "https://github.com/zigbeeprotocol/Z-Fuzzer/tree/master/vulnerabilities",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.ti.com/tool/Z-STACK",
"tags": [
"Product",
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/zigbeeprotocol/Z-Fuzzer/tree/master/vulnerabilities",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.ti.com/tool/Z-STACK",
"tags": [
"Product",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Zigbee protocol implementation on Texas Instruments CC2538 devices with Z-Stack 3.0.1 does not properly process a ZCL Discover Commands Received Response message or a ZCL Discover Commands Generated Response message. It crashes in zclParseInDiscCmdsRspCmd()."
},
{
"lang": "es",
"value": "La implementación del protocolo Zigbee en los dispositivos CC2538 de Texas Instruments con Z-Stack versión 3.0.1, no procesa apropiadamente un mensaje ZCL Discover Commands Received Response o un mensaje ZCL Discover Commands Generated Response. Se bloquea en la función zclParseInDiscCmdsRspCmd()"
}
],
"lastModified": "2026-06-17T03:09:48.010",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ti:z-stack:3.0.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4AD5B078-5BEF-46F9-9174-6A86706C90A5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ti:cc2538:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9F137F5D-7CBF-4B65-ADB1-01FE8ABBFB3C"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}