CVE-2020-27483
Garmin Forerunner 235 before 8.20 is affected by: Array index error. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter trusts the offset provided for the stack value duplication instruction, DUP. The offset is unchecked and memory prior to the start of the execution stack can be read and treated as a TVM object. A successful exploit could use the vulnerability to leak runtime information such as the heap handle or pointer for a number of TVM context variables. Some reachable values may be controlled enough to forge a TVM object on the stack, leading to possible remote code execution.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 9.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.15%
- Percentil entre todas las CVEs puntuadas: 81
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-129
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-27483",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 9.9,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 3.1
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-11-16T21:15:13.300",
"references": [
{
"url": "https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0007.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0007.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-129"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Garmin Forerunner 235 before 8.20 is affected by: Array index error. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter trusts the offset provided for the stack value duplication instruction, DUP. The offset is unchecked and memory prior to the start of the execution stack can be read and treated as a TVM object. A successful exploit could use the vulnerability to leak runtime information such as the heap handle or pointer for a number of TVM context variables. Some reachable values may be controlled enough to forge a TVM object on the stack, leading to possible remote code execution."
},
{
"lang": "es",
"value": "Garmin Forerunner 235 versiones anteriores a 8.20, está afectado por: un Error de Índice de Matriz. El componente es: ConnectIQ TVM. El vector de ataque es: Para explotar la vulnerabilidad, el atacante debe cargar una aplicación de ConnectIQ maliciosa en la tienda ConnectIQ. El intérprete del programa ConnectIQ confía en el desplazamiento proporcionado para la instrucción de duplicación del valor de pila, DUP. El desplazamiento no está marcado y la memoria antes del inicio de la pila de ejecución puede ser leída y tratada como un objeto TVM. Una explotación con éxito podría usar la vulnerabilidad para filtrar información de tiempo de ejecución, como el manejador de pila o el puntero para una serie de variables del contexto de TVM. Algunos valores alcanzables pueden controlarse lo suficiente para falsificar un objeto TVM en la pila, conllevando a una posible ejecución de código remota"
}
],
"lastModified": "2026-06-17T03:09:15.067",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:garmin:forerunner_235_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6043DF86-0FC7-4F8D-A1F4-A8A79BF90099",
"versionEndExcluding": "8.20",
"versionStartIncluding": "7.90"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:garmin:forerunner_235:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "3387D0DB-AB79-4860-B741-CE78FE79139D"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}