« Volver al listado

CVE-2020-27276

Estado: ModificadaMedia (5.7)—

SOOIL Developments Co Ltd DiabecareRS,AnyDana-i & AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i & AnyDana-A mobile apps doesn't use adequate measures to authenticate the communicating entities before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the authentication sequence via Bluetooth Low Energy.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (3)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-27276",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 2.9,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:M/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 5.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.7,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.1
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "SOOIL Developments CoLtd DiabecareRS,AnyDana-i,AnyDana-A",
          "versions": [
            {
              "status": "affected",
              "version": "Dana DiabecareRS, AnyDana-i, AnyDana-A  All versions prior to 3.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-01-19T17:15:12.677",
  "references": [
    {
      "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-012-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-012-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-290"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-290"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "SOOIL Developments Co Ltd DiabecareRS,AnyDana-i & AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i & AnyDana-A mobile apps doesn't use adequate measures to authenticate the communicating entities before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the authentication sequence via Bluetooth Low Energy."
    },
    {
      "lang": "es",
      "value": "SOOIL Developments Co Ltd DiabecareRS, AnyDana-i & AnyDana-A, el protocolo de comunicación de la bomba de insulina y sus aplicaciones móviles AnyDana-i, AnyDana-A no utiliza las medidas adecuadas para autenticar a las entidades comunicantes antes de intercambiar claves, lo que permite no autenticar , los atacantes físicamente próximos para rastrear la secuencia de autenticación por medio de Bluetooth Low Energy"
    }
  ],
  "lastModified": "2026-06-17T03:09:05.897",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sooil:anydana-a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "808DBA89-C2C2-4C03-814D-DB0B4DFF8B22",
              "versionEndExcluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sooil:anydana-a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2624582E-762F-4CDB-B974-1BC971F1544D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sooil:anydana-i_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "98E25B7D-C1ED-4144-8411-171C7B6426E4",
              "versionEndExcluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sooil:anydana-i:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E25CB863-07D9-4E90-8022-6C2B4C52EDFC"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sooil:diabecare_rs_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C5C154F1-7F29-4EC0-9971-76A02C6DA8BC",
              "versionEndExcluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sooil:diabecare_rs:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8628A530-AF34-453E-968A-40DD5B8EE456"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}