« Volver al listado

CVE-2020-27272

Estado: ModificadaMedia (5.7)—

SOOIL Developments CoLtd DiabecareRS, AnyDana-i, AnyDana-A, The communication protocol of the insulin pump and AnyDana-i,AnyDana-A mobile apps doesn't use adequate measures to authenticate the pump before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the keys and spoof the pump via BLE.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (3)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-27272",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 2.9,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:M/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 5.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.7,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.1
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "SOOIL Developments CoLtd DiabecareRS,AnyDana-i,AnyDana-A",
          "versions": [
            {
              "status": "affected",
              "version": "Dana Diabecare RS,AnyDana-i,AnyDana-A versions prior to 3.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-01-19T17:15:12.613",
  "references": [
    {
      "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-012-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-012-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "SOOIL Developments CoLtd DiabecareRS, AnyDana-i, AnyDana-A, The communication protocol of the insulin pump and AnyDana-i,AnyDana-A mobile apps doesn't use adequate measures to authenticate the pump before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the keys and spoof the pump via BLE."
    },
    {
      "lang": "es",
      "value": "SOOIL Developments CoLtd DiabecareRS, AnyDana-i, AnyDana-A, El protocolo de comunicación de la bomba de insulina y las aplicaciones móviles AnyDana-i, AnyDana-A no utilizan las medidas adecuadas para autenticar la bomba antes de intercambiar claves, lo que permite no autenticarse a atacantes físicamente cerca para escuchar las claves y falsificar la bomba por medio de BLE"
    }
  ],
  "lastModified": "2026-06-17T03:09:05.573",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sooil:anydana-a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "808DBA89-C2C2-4C03-814D-DB0B4DFF8B22",
              "versionEndExcluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sooil:anydana-a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2624582E-762F-4CDB-B974-1BC971F1544D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sooil:anydana-i_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "98E25B7D-C1ED-4144-8411-171C7B6426E4",
              "versionEndExcluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sooil:anydana-i:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E25CB863-07D9-4E90-8022-6C2B4C52EDFC"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sooil:diabecare_rs_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C5C154F1-7F29-4EC0-9971-76A02C6DA8BC",
              "versionEndExcluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sooil:diabecare_rs:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8628A530-AF34-453E-968A-40DD5B8EE456"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}