CVE-2020-27228
Estado: ModificadaAlta (7.8)—
An incorrect default permissions vulnerability exists in the installation functionality of OpenClinic GA 5.173.3. Overwriting the binary can result in privilege escalation. An attacker can replace a file to exploit this vulnerability.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.76%
- Percentil entre todas las CVEs puntuadas: 54
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-276
- CWE-276
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-27228",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 8.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 2
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "talos-cna@cisco.com",
"affectedData": [
{
"vendor": "n/a",
"product": "OpenClinic",
"versions": [
{
"status": "affected",
"version": "OpenClinic GA 5.173.3"
}
]
}
]
}
],
"published": "2021-04-13T15:15:12.853",
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1204",
"tags": [
"Exploit",
"Technical Description",
"Third Party Advisory"
],
"source": "talos-cna@cisco.com"
},
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1204",
"tags": [
"Exploit",
"Technical Description",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-276"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-276"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An incorrect default permissions vulnerability exists in the installation functionality of OpenClinic GA 5.173.3. Overwriting the binary can result in privilege escalation. An attacker can replace a file to exploit this vulnerability."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de permisos predeterminados incorrectos en la funcionalidad installation de OpenClinic GA versión 5.173.3. Sobrescribir el binario puede resultar en una escalada de privilegios. Un atacante puede reemplazar un archivo para explotar esta vulnerabilidad"
}
],
"lastModified": "2026-06-17T03:09:00.750",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.173.3:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9A9D3102-92E5-4526-BAD4-F3DE62BA2205"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "talos-cna@cisco.com"
}