« Volver al listado

CVE-2020-26081

Estado: ModificadaMedia (6.1)—

Multiple vulnerabilities in the web UI of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to conduct cross-site scripting (XSS) attacks against users on an affected system. The vulnerabilities are due to insufficient validation of user-supplied input that is processed by the web UI. An attacker could exploit these vulnerabilities by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information on an affected system.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-26081",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2020-26081",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-13T17:22:12.471359Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "psirt@cisco.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@cisco.com",
      "affectedData": [
        {
          "vendor": "Cisco",
          "product": "Cisco IoT Field Network Director (IoT-FND)",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-11-18T18:15:12.167",
  "references": [
    {
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-XSS-NzOPCGEc",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "psirt@cisco.com"
    },
    {
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-XSS-NzOPCGEc",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple vulnerabilities in the web UI of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to conduct cross-site scripting (XSS) attacks against users on an affected system. The vulnerabilities are due to insufficient validation of user-supplied input that is processed by the web UI. An attacker could exploit these vulnerabilities by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information on an affected system."
    },
    {
      "lang": "es",
      "value": "Múltiples vulnerabilidades en la interfaz de usuario web de Cisco IoT Field Network Director (FND), podrían permitir a un atacante remoto no autenticado llevar a cabo ataques de tipo cross-site scripting (XSS) contra usuarios en un sistema afectado. Las vulnerabilidades son debido a una comprobación insuficiente de la entrada suministrada por el usuario que es procesada por la interfaz de usuario web. Un atacante podría explotar estas vulnerabilidades persuadiendo a un usuario para que haga clic en un enlace creado. Una explotación con éxito podría permitir al atacante ejecutar código de secuencia de comandos arbitrario en el contexto de la interfaz o acceder a información confidencial basada en navegador en un sistema afectado"
    }
  ],
  "lastModified": "2026-06-17T03:07:34.377",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0D507A4F-4079-4B68-997E-88901E063348",
              "versionEndExcluding": "4.6.1"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "psirt@cisco.com"
}