Multiple vulnerabilities in the web UI of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to conduct cross-site scripting (XSS) attacks against users on an affected system. The vulnerabilities are due to insufficient validation of user-supplied input that is processed by the web UI. An attacker could exploit these vulnerabilities by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information on an affected system.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
- Puntuación base: 6.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.80%
- Percentil entre todas las CVEs puntuadas: 55
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-74
- CWE-74
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-26081",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2020-26081",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-11-13T17:22:12.471359Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 6.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.8
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@cisco.com",
"affectedData": [
{
"vendor": "Cisco",
"product": "Cisco IoT Field Network Director (IoT-FND)",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-11-18T18:15:12.167",
"references": [
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-XSS-NzOPCGEc",
"tags": [
"Vendor Advisory"
],
"source": "psirt@cisco.com"
},
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-XSS-NzOPCGEc",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-74"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-74"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple vulnerabilities in the web UI of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to conduct cross-site scripting (XSS) attacks against users on an affected system. The vulnerabilities are due to insufficient validation of user-supplied input that is processed by the web UI. An attacker could exploit these vulnerabilities by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information on an affected system."
},
{
"lang": "es",
"value": "Múltiples vulnerabilidades en la interfaz de usuario web de Cisco IoT Field Network Director (FND), podrían permitir a un atacante remoto no autenticado llevar a cabo ataques de tipo cross-site scripting (XSS) contra usuarios en un sistema afectado. Las vulnerabilidades son debido a una comprobación insuficiente de la entrada suministrada por el usuario que es procesada por la interfaz de usuario web. Un atacante podría explotar estas vulnerabilidades persuadiendo a un usuario para que haga clic en un enlace creado. Una explotación con éxito podría permitir al atacante ejecutar código de secuencia de comandos arbitrario en el contexto de la interfaz o acceder a información confidencial basada en navegador en un sistema afectado"
}
],
"lastModified": "2026-06-17T03:07:34.377",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0D507A4F-4079-4B68-997E-88901E063348",
"versionEndExcluding": "4.6.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "psirt@cisco.com"
}