CVE-2020-26076
Estado: ModificadaAlta (7.5)—
A vulnerability in Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to view sensitive database information on an affected device. The vulnerability is due to the absence of authentication for sensitive information. An attacker could exploit this vulnerability by sending crafted curl commands to an affected device. A successful exploit could allow the attacker to view sensitive database information on the affected device.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.33%
- Percentil entre todas las CVEs puntuadas: 70
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-497
- CWE-200
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-26076",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2020-26076",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-11-13T17:12:04.030325Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "psirt@cisco.com",
"affectedData": [
{
"vendor": "Cisco",
"product": "Cisco IoT Field Network Director (IoT-FND)",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-11-18T18:15:11.730",
"references": [
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-SSI-V2myWX9y",
"tags": [
"Vendor Advisory"
],
"source": "psirt@cisco.com"
},
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-SSI-V2myWX9y",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-497"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to view sensitive database information on an affected device. The vulnerability is due to the absence of authentication for sensitive information. An attacker could exploit this vulnerability by sending crafted curl commands to an affected device. A successful exploit could allow the attacker to view sensitive database information on the affected device."
},
{
"lang": "es",
"value": "Una vulnerabilidad en Cisco IoT Field Network Director (FND), podría permitir a un atacante remoto no autenticado visualizar información confidencial de la base de datos en un dispositivo afectado. La vulnerabilidad es debido a la ausencia de autenticación de la información confidencial. Un atacante podría explotar esta vulnerabilidad mediante el envío comandos curl diseñados a un dispositivo afectado. Una explotación con éxito podría permitir al atacante visualizar información confidencial de la base de datos en el dispositivo afectado"
}
],
"lastModified": "2026-06-17T03:07:33.760",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0D507A4F-4079-4B68-997E-88901E063348",
"versionEndExcluding": "4.6.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "psirt@cisco.com"
}