CVE-2020-24987
Estado: ModificadaCrítica (9.8)—
Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to "radius".
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 3.10%
- Percentil entre todas las CVEs puntuadas: 87
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-287
Referencias
- https://cwe.mitre.org/data/definitions/287.html
- https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing
- https://www.tendacn.com/en/product/AC18.html
- https://cwe.mitre.org/data/definitions/287.html
- https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing
- https://www.tendacn.com/en/product/AC18.html
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-24987",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-09-04T20:15:13.480",
"references": [
{
"url": "https://cwe.mitre.org/data/definitions/287.html",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing",
"tags": [
"Broken Link"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.tendacn.com/en/product/AC18.html",
"tags": [
"Product",
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://cwe.mitre.org/data/definitions/287.html",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing",
"tags": [
"Broken Link"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.tendacn.com/en/product/AC18.html",
"tags": [
"Product",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to \"radius\"."
},
{
"lang": "es",
"value": "El enrutador Tenda AC18 versiones hasta V15.03.05.05_EN y versiones hasta V15.03.05.19(6318), los dispositivos CN podrían causar una ejecución remota de código debido a un manejo de autenticación incorrecto de la función vulnerable logincheck() en el archivo /usr/lib/lua/ngx_authserver/ngx_wdas.lua si la interfaz de usuario del administrador está configurada en \"radius\""
}
],
"lastModified": "2026-06-17T03:06:12.747",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5798E4A8-6F1D-45DB-A253-88033163218C",
"versionEndIncluding": "v15.03.05.05_en"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "677F497C-FD6E-4A6C-A7A9-281E5453A78B",
"versionEndIncluding": "v15.03.05.19\\(6318\\)_cn"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}