« Volver al listado

CVE-2020-24509

Estado: ModificadaMedia (6.7)—

Insufficient control flow management in subsystem in Intel(R) SPS versions before SPS_E3_05.01.04.300.0, SPS_SoC-A_05.00.03.091.0, SPS_E5_04.04.04.023.0, or SPS_E5_04.04.03.263.0 may allow a privileged user to potentially enable escalation of privilege via local access.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-24509",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.6,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.7,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.8
      }
    ]
  },
  "affected": [
    {
      "source": "secure@intel.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Intel(R) SPS versions",
          "versions": [
            {
              "status": "affected",
              "version": "versions before SPS_E3_05.01.04.300.0, SPS_SoC-A_05.00.03.091.0, SPS_E5_04.04.04.023.0, or SPS_E5_04.04.03.263.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-06-09T19:15:08.863",
  "references": [
    {
      "url": "https://security.netapp.com/advisory/ntap-20210611-0003/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "secure@intel.com"
    },
    {
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00459.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "secure@intel.com"
    },
    {
      "url": "https://security.netapp.com/advisory/ntap-20210611-0003/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00459.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Insufficient control flow management in subsystem in Intel(R) SPS versions before SPS_E3_05.01.04.300.0, SPS_SoC-A_05.00.03.091.0, SPS_E5_04.04.04.023.0, or SPS_E5_04.04.03.263.0 may allow a privileged user to potentially enable escalation of privilege via local access."
    },
    {
      "lang": "es",
      "value": "Una administración insuficiente del flujo de control en el subsistema en Intel® SPS versiones anteriores a SPS_E3_05.01.04.300.0, SPS_SoC-A_05.00.03.091.0, SPS_E5_04.04.04.023.0 o SPS_E5_04.04.03.263.0, puede habilitar a un usuario privilegiado para permitir potencialmente una escalada de privilegios por medio de un acceso local"
    }
  ],
  "lastModified": "2026-06-17T03:05:42.010",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:intel:server_platform_services:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2ACF24BE-B526-480C-B381-F0A8E92128CF",
              "versionEndExcluding": "sps_soc-a_05.00.03.091.0"
            },
            {
              "criteria": "cpe:2.3:a:intel:server_platform_services:sps_e3_05.01.04.300.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D469B164-E8B4-44AD-922E-C5A038F16BBB"
            },
            {
              "criteria": "cpe:2.3:a:intel:server_platform_services:sps_e5_04.04.03.263.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D69B8A8D-C9D6-49E5-9CD1-74E18BD98683"
            },
            {
              "criteria": "cpe:2.3:a:intel:server_platform_services:sps_e5_04.04.04.023.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "51C70681-4446-4481-93FB-8666CDC41064"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "secure@intel.com"
}