« Volver al listado

CVE-2020-14485

Estado: ModificadaCrítica (9.8)—

OpenClinic GA versions 5.09.02 and 5.89.05b may allow an attacker to bypass client-side access controls or use a crafted request to initiate a session with limited functionality, which may allow execution of admin functions such as SQL queries.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-14485",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "OpenClinic GA",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 5.09.02 and 5.89.05b"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-07-20T15:15:12.740",
  "references": [
    {
      "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-288"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "OpenClinic GA versions 5.09.02 and 5.89.05b may allow an attacker to bypass client-side access controls or use a crafted request to initiate a session with limited functionality, which may allow execution of admin functions such as SQL queries."
    },
    {
      "lang": "es",
      "value": "OpenClinic GA versiones 5.09.02 y 5.89.05b, pueden permitir a un atacante omitir los controles de acceso del lado del cliente o usar una petición diseñada para iniciar una sesión con una funcionalidad limitada, lo que puede permitir una ejecución de funcionalidades administrativas tales como consultas SQL"
    }
  ],
  "lastModified": "2026-06-17T02:54:50.980",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.09.02:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A64E5CCD-1F0D-46B2-9AE7-C917928D2788"
            },
            {
              "criteria": "cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.89.05b:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BE2E5CDB-B864-45E4-A7EA-D7EE93BC2453"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],