CVE-2020-12043
Estado: ModificadaCrítica (9.8)—
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.10%
- Percentil entre todas las CVEs puntuadas: 81
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-672
- CWE-672
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-12043",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "Baxter Sigma Spectrum Infusion Pumps",
"versions": [
{
"status": "affected",
"version": "Sigma Spectrum v6.x model 35700BAX, Baxter Spectrum v8.x model 35700BAX2,Sigma Spectrum v6.x with Wireless Battery Module v9,11,13,14,15,16,v20D29,v20D30,v20D31,v22D24, Baxter Spectrum v8.x with Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24,Baxter Spectrum Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24,Baxter Spectrum LVP v8.x w/Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24"
}
]
}
]
}
],
"published": "2020-06-29T14:15:11.817",
"references": [
{
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-672"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-672"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted."
},
{
"lang": "es",
"value": "El Baxter Spectrum WBM (versiones v17, v20D29, v20D30, v20D31 y v22D24) cuando está configurado para redes inalámbricas, el servicio FTP que opera en el WBM permanece operativo hasta que el WBM es reiniciado"
}
],
"lastModified": "2026-06-17T02:51:20.060",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "72D0F7CB-3D24-4A8D-826D-ACB20ACBEB1C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "49E25260-EC14-4E98-A86B-CBBE47E26AE5"
},
{
"criteria": "cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7DD7F5A5-FDC7-4976-910E-C1AFD2D61BA3"
},
{
"criteria": "cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "30CE6E9A-4921-46B4-946D-A84A92F99855"
},
{
"criteria": "cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CB987049-C099-482C-83FB-ECBF43C71DE5"
},
{
"criteria": "cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "89077083-BD72-499F-8628-F34052747F01"
},
{
"criteria": "cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FE329FD7-E3C9-4908-8273-231BF132915D"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}