Estado: ModificadaMedia (4.9)—

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-12035",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 3.6,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 4.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.9,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 4.2,
        "exploitabilityScore": 0.7
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Baxter PrismaFlex and PrisMax",
          "versions": [
            {
              "status": "affected",
              "version": "PrismaFlex all versions, PrisMax all versions prior to 3.x"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-06-29T14:15:11.397",
  "references": [
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01",
      "tags": [
        "Not Applicable"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-170-02",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "nvd@nist.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01",
      "tags": [
        "Not Applicable"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration."
    },
    {
      "lang": "es",
      "value": "Baxter PrismaFlex todas las versiones, PrisMax todas las versiones anteriores a 3.x, el dispositivo PrismaFlex, contiene una contraseña de servicio embebida que proporciona acceso a información biomédica, configuración del dispositivo, configuración de calibración y configuración de red. Esto podría permitir a un atacante modificar la configuración y la calibración del dispositivo"
    }
  ],
  "lastModified": "2026-06-17T02:51:18.567",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:baxter:prismaflex_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B8874804-02E2-4E74-94C6-F103DCDC854E"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:baxter:prismaflex:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8E5DB2B2-5D9E-494B-A860-FE2F4BC4C767"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:baxter:prismax_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8F197DAD-63A3-4598-BBFC-0014707B3A01",
              "versionEndExcluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:baxter:prismax:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A5EB1A30-A514-437D-B976-451CF003955D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "evaluatorComment": "At the time of analysis, information provided did not align with the data (including CVE number) in the advisory.",
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}