CVE-2020-11766
Estado: ModificadaAlta (8.8)—
sendfax.php in iFAX AvantFAX before 3.3.6 and HylaFAX Enterprise Web Interface before 0.2.5 allows authenticated Command Injection.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.85%
- Percentil entre todas las CVEs puntuadas: 78
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-78
Referencias
- ftp://ftp.ifax.com/security/CVE-2020-11766.html
- ftp://ftp.ifax.com/security/CVE-2020-11766.html
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-11766",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-05-19T20:15:10.023",
"references": [
{
"url": "ftp://ftp.ifax.com/security/CVE-2020-11766.html",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "ftp://ftp.ifax.com/security/CVE-2020-11766.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "sendfax.php in iFAX AvantFAX before 3.3.6 and HylaFAX Enterprise Web Interface before 0.2.5 allows authenticated Command Injection."
},
{
"lang": "es",
"value": "El archivo sendfax.php en iFAX AvantFAX versiones anteriores a 3.3.6 e HylaFAX Enterprise Web Interface versiones anteriores a 0.2.5, permite una Inyección de Comandos autenticada."
}
],
"lastModified": "2026-06-17T02:50:45.433",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ifax:hylafax:*:*:*:*:enterprise:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4B1AA8A8-B7C3-4AC5-BDA8-10CEB95E9E6C",
"versionEndExcluding": "0.2.5",
"versionStartIncluding": "0.2.0"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:avantfax:avantfax:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D98C5993-839A-49A1-9404-59B97ED4E11D",
"versionEndExcluding": "3.3.6",
"versionStartIncluding": "3.3.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}