CVE-2020-10627
Estado: ModificadaAlta (8.1)—
Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.49%
- Percentil entre todas las CVEs puntuadas: 40
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-284
- NVD-CWE-Other
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-10627",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.8,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 4.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.5,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 4.7,
"exploitabilityScore": 2.5
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Insulet",
"product": "Omnipod Insulin Management System",
"versions": [
{
"status": "affected",
"version": "19191"
},
{
"status": "affected",
"version": "40160"
},
{
"status": "affected",
"version": "ZXP425"
},
{
"status": "affected",
"version": "ZXR425"
}
]
}
]
}
],
"published": "2021-12-01T16:15:07.390",
"references": [
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-079-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.myomnipod.com/security-bulletins",
"tags": [
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-079-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.myomnipod.com/security-bulletins",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery."
},
{
"lang": "es",
"value": "La bomba de insulina Insulet Omnipod Insulin Management System, con ID de producto 19191 y 40160, está diseñada para comunicarse mediante RF inalámbrica con un dispositivo de administración personal de la diabetes fabricado por Insulet. Este protocolo de comunicación de RF inalámbrica no implementa apropiadamente la autenticación o la autorización. Un atacante con acceso a uno de los modelos de bomba de insulina afectados podría ser capaz de modificar y/o interceptar datos. Esta vulnerabilidad también podría permitir a atacantes cambiar la configuración de la bomba y controlar la administración de insulina"
}
],
"lastModified": "2026-06-17T02:48:07.520",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:insulet:omnipod_insulin_management_system_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FC41AB2D-AB47-41B7-AEBA-AB4C0A8608A5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:insulet:omnipod_insulin_management_system:19191:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "98184BD3-4593-4194-A00C-9C064BE96144"
},
{
"criteria": "cpe:2.3:h:insulet:omnipod_insulin_management_system:40160:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7AF53C0A-02F1-4F3C-996F-E0E5269034C2"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}