CVE-2019-7670
Estado: ModificadaAlta (7.2)—
Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 18%
- Percentil entre todas las CVEs puntuadas: 97
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
- http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html
- https://applied-risk.com/labs/advisories
- https://www.us-cert.gov/ics/advisories/icsa-19-211-02
- https://www.applied-risk.com/resources/ar-2019-007
- http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html
- https://applied-risk.com/labs/advisories
- https://www.us-cert.gov/ics/advisories/icsa-19-211-02
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-7670",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-07-01T19:15:11.790",
"references": [
{
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"source": "cve@mitre.org"
},
{
"url": "https://applied-risk.com/labs/advisories",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.applied-risk.com/resources/ar-2019-007",
"tags": [
"Third Party Advisory"
],
"source": "nvd@nist.gov"
},
{
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://applied-risk.com/labs/advisories",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system."
},
{
"lang": "es",
"value": "Los dispositivos Prima Systems FlexAir, versiones 2.3.38 y anteriores. La aplicación neutraliza incorrectamente elementos especiales que podrían modificar el comando del sistema operativo deseado cuando se envía a un componente posterior, lo que podría permitir a los atacantes ejecutar comandos directamente en el sistema operativo."
}
],
"lastModified": "2026-06-17T02:40:50.487",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}