« Volver al listado

CVE-2019-6812

Estado: ModificadaAlta (7.2)—

Una CWE-798: Una vulnerabilidad de uso de credenciales codificadas en BMX-NOR-0200H con versiones de firmware anteriores a V1.7 IR 19, podría generar un problema de confidencialidad cuando se usa protocolo FTP.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-6812",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
          "authentication": "SINGLE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Modicon RTU Module, BMX-NOR-0200H with firmware versions prior to V1.7 IR 19",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon RTU Module, BMX-NOR-0200H with firmware versions prior to V1.7 IR 19"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-05-22T20:29:01.933",
  "references": [
    {
      "url": "https://security.cse.iitk.ac.in/responsible-disclosure",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://security.cse.iitk.ac.in/responsible-disclosure",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol."
    },
    {
      "lang": "es",
      "value": "Una CWE-798: Una vulnerabilidad de uso de credenciales codificadas en BMX-NOR-0200H con versiones de firmware anteriores a V1.7 IR 19, podría generar un problema de confidencialidad cuando se usa protocolo FTP."
    }
  ],
  "lastModified": "2026-06-17T02:39:43.563",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:bmx-nor-0200h_firmware:1.7:ir17:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4AC01C51-0353-4B7C-A127-432E4840CF15"
            },
            {
              "criteria": "cpe:2.3:o:schneider-electric:bmx-nor-0200h_firmware:1.7:ir18:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B711592B-3CA5-446E-BB55-2E79541EB02C"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:bmx-nor-0200h:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B0A315A6-23AF-4F9C-886E-D87E100D865B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}